;================================================================= ; GSD file per TKM60-Profibus TEKEL INSTRUMENTS S.r.l. ; Version : (V0.1)-(Tekel Instruments S.r.l. +39 121 343811) ; Copyright (C) TEKEL INSTRUMENTS S.r.l. (2001) ; All Rights Reserved. ; ; Revisione del 13/11/2003 ;================================================================= #Profibus_DP PrmText=1 Text(0)="Clockwise (0)" Text(1)="Counterclockwise (1)" EndPrmText PrmText=2 Text(0)="Disabled" Text(1)="Enabled" EndPrmText PrmText=3 Text(0)="Suspended" Text(1)="Activated" EndPrmText ExtUserPrmData=1 "Code sequence" Bit(0) 0 0-1 Prm_Text_Ref=1 EndExtUserPrmData ExtUserPrmData=2 "Class 2 functionality" Bit(1) 0 0-1 Prm_Text_Ref=2 EndExtUserPrmData ExtUserPrmData=3 "Simulation speed" Unsigned8 100 1-255 EndExtUserPrmData ExtUserPrmData=4 "Simulation" Bit(0) 0 0-1 Prm_Text_Ref=2 EndExtUserPrmData ExtUserPrmData=5 "Simulation count" Bit(1) 0 0-1 Prm_Text_Ref=3 EndExtUserPrmData ExtUserPrmData=6 "Scaling" Bit(3) 0 0-1 Prm_Text_Ref=2 EndExtUserPrmData ExtUserPrmData=7 "Measuring units per revolution" Unsigned32 8192 1-8192 EndExtUserPrmData ExtUserPrmData=8 "Total measuring range" Unsigned32 33554432 1-33554432 EndExtUserPrmData ExtUserPrmData=9 "Diagnostic mode" Unsigned8 0 0-3 EndExtUserPrmData Unit_Diag_Bit(0)="Position error" Unit_Diag_Bit(1)="Supply voltage error" Unit_Diag_Bit(2)="Current too high" Unit_Diag_Bit(3)="Commissioning diagnostic" Unit_Diag_Bit(4)="Memory error" Unit_Diag_Bit(5)="Errore #1" Unit_Diag_Bit(6)="Errore #2" Unit_Diag_Bit(7)="Errore #3" ; ; ; GSD_Revision = 2 Vendor_Name = "Tekel Instruments S.r.l." Model_Name = "TKM60-PB3" Revision = "0.02" Ident_Number = 0x06B3 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 DP_Encoder_class = 1 DP_Encoder_profile_version = 1.1 DP_Encoder_manufacturer_specific_functions = true Hardware_Release = "V0.01" Software_Release = "V0.05" ; 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTSDR_12M = 800 ; Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 Implementation_Type = "SPC3" Bitmap_Device="TKM306B3" OrderNumber="TKM60-PBnnx" Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 Min_Slave_Intervall = 6 Modular_Station = 1 Max_Module = 1 Fail_Safe = 0 ; Max_Diag_Data_Len = 64 Modul_Offset = 1 Slave_Family = 7 Max_Input_Len=4 Max_Output_Len=4 Max_Data_Len=8 Max_User_Prm_Data_Len=13 ; ; ;User_Prm_Data_Len = 5 ;User_Prm_Data = 0x01,0x02,0x03,0x04,0x05 ; ; Module = "Class 1 Singleturn" 0xD0 Ext_Module_Prm_Data_Len = 5 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x64,0x00,0x00 Ext_User_Prm_Data_Ref(1)=1 ; Code sequence Ext_User_Prm_Data_Ref(2)=3 ; Simulation speed Ext_User_Prm_Data_Ref(3)=4 ; Simulation Ext_User_Prm_Data_Ref(3)=5 ; Simulation count Ext_User_Prm_Data_Ref(4)=9 ; Diagnostic mode EndModule Module = "Class 1 Multiturn" 0xD1 Ext_Module_Prm_Data_Len = 5 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x64,0x00,0x00 Ext_User_Prm_Data_Ref(1)=1 ; Code sequence Ext_User_Prm_Data_Ref(2)=3 ; Simulation speed Ext_User_Prm_Data_Ref(3)=4 ; Simulation Ext_User_Prm_Data_Ref(3)=5 ; Simulation count Ext_User_Prm_Data_Ref(4)=9 ; Diagnostic mode EndModule Module = "Class 2 Singleturn" 0xF0 Ext_Module_Prm_Data_Len = 13 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x64,0x00,0x00 Ext_User_Prm_Data_Ref(1)=1 ; Code sequence Ext_User_Prm_Data_Ref(1)=2 ; Class 2 functionality Ext_User_Prm_Data_Ref(1)=6 ; Scaling Ext_User_Prm_Data_Ref(2)=7 ; Measuring units per revolution Ext_User_Prm_Data_Ref(6)=8 ; Total measuring range Ext_User_Prm_Data_Ref(10)=3 ; Simulation speed Ext_User_Prm_Data_Ref(11)=4 ; Simulation Ext_User_Prm_Data_Ref(11)=5 ; Simulation count Ext_User_Prm_Data_Ref(12)=9 ; Diagnostic mode EndModule Module = "Class 2 Multiturn" 0xF1 Ext_Module_Prm_Data_Len = 13 Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x00,0x64,0x00,0x00 Ext_User_Prm_Data_Ref(1)=1 ; Code sequence Ext_User_Prm_Data_Ref(1)=2 ; Class 2 functionality Ext_User_Prm_Data_Ref(1)=6 ; Scaling Ext_User_Prm_Data_Ref(2)=7 ; Measuring units per revolution Ext_User_Prm_Data_Ref(6)=8 ; Total measuring range Ext_User_Prm_Data_Ref(10)=3 ; Simulation speed Ext_User_Prm_Data_Ref(11)=4 ; Simulation Ext_User_Prm_Data_Ref(11)=5 ; Simulation count Ext_User_Prm_Data_Ref(12)=9 ; Diagnostic mode EndModule